SI Units

 [US Units] [SI Units]

Square/Rectangular Flue Liners

Round Flue Liners (Below)

Size (mm)

Outside Dim (mm)

Inside Dim (mm)

Inside cross-section al Area (cm2)

Wall Thicknes s (mm)

8"x8"  (203x203)*

200x200

175x175

305 cm2

16 mm

8½"x8½"
(216x216)

216x216

178x178

316 cm2

19 mm

8"x12" (203x305)*

191x292

152x254

387 cm2

19 mm

8½"x13"
(216x330)

216x330

165x279

461 cm2

25 mm

10"x10" (254x254)

254x254

210x210

441 cm2

22 mm

12"x12"
(305x305)*

318x318

248x248

614 cm2

19 mm

13"x13" (330x330)

292x394

279x279

781 cm2

19 mm

11½"x15½"
(292x394)*

330x445

235x330

776 cm2

32 mm

13"x18" (330x457)

381x394

273x394

1075 cm2

25 mm

15½"x15½"
(394x394)*

381x394

330x337

1130 cm2

25 mm

18"x18" (457x457)

445x445

381x381

1452 cm2

32 mm

16"x20" (406x508)

381x489

330x432

1426 cm2

32 mm

20"x20" (508x508)

489x489

419x419

1757 cm2

35 mm

20"x24" (508x610)

495x584

413x514

2123 cm2

41 mm

24"x24" (610x610)

610x610

521x521

2712 cm2

44 mm

    *Designates modular flue sizes.  Modular flues are designed for use with modular brick sizes.  Non-modular flue liners are designed for standard size brick.  As a general rule, modular flues should be used whenever possible because they make construction easier and less costly.

Picture

Round Flue Liners

Size (mm)

Outside Dim (mm)

Inside Diameter (mm)

Inside cross-section al Area (cm2)

Wall Thickness (mm)

4" Round (102 mm)

133 mm

102 mm

81 cm2

16 mm

6" Round (152 mm)

190 mm

152 mm

182 cm2

19 mm

7" Round (178 mm)

222 mm

178 mm

248 cm2

22 mm

8" Round (203 mm)

254 mm

203 mm

325 cm2

25 mm

10" Round (254 mm)

305 mm

254 mm

506 cm2

25 mm

12" Round (305 mm)

356 mm

305 mm

729 cm2

25 mm